- Incorrect time in instrument cluster and head unit on NTG 6 vehicles with Connect MID (code 548) without hard disk navigation (code 365) (For internal use only!) -

主题编号
LI82.85-P-072013
版本
2
功能组
82.85 Navigation and Communication systems
日期
12-28-2020
有效性
Models 118, 167, 177, 213, 238, 247, 253, 257 and X290 with Connect 20 MID (code 548) with hard disk navigation (code 365).
更改原因
Country distribution adjusted

投诉

- The time shown in the display cluster A40/16 (head unit and instrument cluster) is incorrect.
- When starting up after an extended period of non-operational time (e.g. overnight), the wrong time is shown in the display cluster A40/16 (head unit and instrument cluster); after bus idle and a restart, the correct time is shown again.


原因

Faulty HERMES software


补救

Use XENTRY Diagnosis to perform a software update of the HERMES communication module (N112/9) to software version number: E522.3 or newer.

Note:

It is possible that the HERMES SW E522.3 may not yet be available through XENTRY Diagnosis for all markets.

If this is the case for the complaint in question, please create a TIPS case, which should be routed directly to technical support team.

Please attach an up-to-date HERMES control unit log to the TIPS case.

.


症状
症状
Communication/information / Information display / Displays / Clock / Too fast

操作号/损坏代码
操作号
操作内容
时间
损坏代码
提示
54-0991 Program and code control unit .................... (After quick test) 0.3Hrs 8209Z52